Corrosion is the spontaneous tendency of metals to revert to lower-energy, oxidized states.
This tendency provides the thermodynamic driving force for corrosion; whether corrosion actually proceeds—and how fast—depends on kinetics and environment. Engineers need a firm grip on both to select materials, design protection, and predict service life.
Two broad regimes dominate: aqueous corrosion (metals in liquid electrolytes, usually water) and gaseous/high-temperature corrosion (metals in reactive gases). In aqueous systems, corrosion is an electrochemical process. Anodic regions oxidize metal atoms to ions while cathodic regions consume electrons via reactions such as oxygen reduction or hydrogen evolution. Because these reactions occur at an electrified interface, the electrode potential—set by the double layer at the metal/electrolyte boundary—governs what reactions are possible and at what rate. Thermodynamics relates cell free energy to measurable voltage via ΔG = −nFΔE, and the Nernst equation shows how potential shifts with concentration or pH. To compare electrodes, potentials are reported versus a reference electrode; the Standard Hydrogen Electrode (SHE) anchors this scale. Practical measurements use three-electrode cells (working, reference, counter) to isolate the working electrode’s potential and mitigate errors such as ohmic (IR) drop. Because reference types differ, engineers convert between scales (e.g., Cu/CuSO₄ to SHE) before using E–pH (Pourbaix) diagrams to judge whether a metal is immune, passive, or actively corroding at a given potential and pH.
In gaseous/high-temperature corrosion, electrochemical models are less helpful; the rate is controlled by solid-state diffusion through a growing oxide scale. Oxidant species adsorb on the surface, oxide nucleates and grows, and transport of ions/electrons through the scale controls kinetics. Protective oxides (e.g., Al₂O₃ or Cr₂O₃ on appropriate alloys) can slow growth dramatically, but stresses, microcracking, and spallation can expose fresh metal and accelerate attack. Alloy selection and coatings are primary defenses. Related ionic systems like molten salts behave differently from water: they are essentially fully ionic media, and cell stability and side reactions must be considered when extracting thermodynamic data.
Quantifying damage is central. Methods split into cumulative (mass loss, thickness loss, coupon exposure) and instantaneous electrochemical techniques. The latter—linear polarization resistance (LPR), potentiodynamic scans, and electrochemical impedance spectroscopy (EIS)—deliver real-time rates, reveal thresholds for pitting/crevice corrosion, and help evaluate inhibitors, coatings, or cathodic protection. Practical programs blend both approaches: use fast electrochemical screens to map safe operating windows, then confirm long-term performance with exposures.
Ultimately, corrosion control is a multidisciplinary design exercise: understand the thermodynamics to know what can happen, use kinetics and transport to see how fast it will happen, measure rigorously to verify assumptions, and implement layered defenses—materials selection, environment control, protective films/coatings, inhibitors, and cathodic/anodic protection. With these fundamentals, engineers can diagnose mechanisms, prevent failures, and extend the life of metallic systems in pipelines, pressure equipment, marine structures, power plants, and beyond.

In practice, corrosion requires three elements:
Anodic reaction (metal oxidation): M → Mⁿ⁺ + ne⁻
Cathodic reaction (electron consumption): commonly O₂ + 2H₂O + 4e⁻ → 4OH⁻ or 2H⁺ + 2e⁻ → H₂
Ionic/electronic pathways to close the circuit (electrolyte conductivity and metallic continuity).
2) Aqueous Corrosion: The Electrochemical Framework
Aqueous corrosion occurs in electrolytes—usually water with dissolved ions. At the metal/solution interface, a double layer develops and defines the electrode potential, a central quantity in both thermodynamics and kinetics.
Free energy and voltage:
The maximum electrical work of a cell links to free energy: ΔG = −nFΔE, where n is the number of electrons, F is Faraday’s constant, and ΔE is the cell electromotive force (emf). A negative ΔG indicates a spontaneous reaction.
Nernst behavior:
For a general redox couple, the Nernst equation shows how electrode potential shifts with activities/concentrations and pH. This is the basis for predicting how environment changes (e.g., dilution, acidification, oxygen content) move a system toward or away from corrosion or passivity.
Reference electrodes and scales:
Absolute potentials cannot be measured directly, so potentials are reported relative to a reference. The Standard Hydrogen Electrode (SHE) defines zero. Practical references (Ag/AgCl, saturated calomel, Cu/CuSO₄) are used in the field and then converted to SHE (or another chosen scale) for analysis and for Pourbaix diagrams.
Three-electrode cells and IR drop:
To measure the working electrode potential accurately while current flows, a three-electrode setup is used: working (test) electrode, reference electrode (no current), and counter electrode (carries current). A high-impedance voltmeter protects the reference from polarization. The IR drop (ohmic voltage loss in the electrolyte) can skew readings; Luggin capillaries minimize this distance-dependent error, and current interruption techniques can separate polarization from resistive loss.
Pourbaix (E–pH) diagrams:
These thermodynamic maps show, for a given element, where the metal is immune, passive (protected by a stable film), or corroding at combinations of potential and pH. They help frame possibilities, but they do not guarantee kinetics—films predicted to exist may be slow to form or quick to break down under real-world conditions (chlorides, flow, deposits).
3) Ion Hydration and Transport: Why Electrolytes Matter
Ions in water carry a hydration shell—a tightly bound primary sheath of oriented water molecules and a looser secondary sheath that responds to the ion’s electric field. Cations, with higher field strength near the ion, often bind more primary water molecules than anions. Hydration affects mobility, conductivity, and the structure of the double layer, influencing both measured potentials and corrosion rates. In short: the electrolyte is not a passive bystander; its composition, pH, temperature, and conductivity shape corrosion outcomes.
4) Corrosion in Gases and at High Temperature: Diffusion Rules
When metals face gaseous environments (air, steam, SO₂, H₂S, CO₂) at elevated temperature, corrosion is governed less by solution electrochemistry and more by solid-state diffusion through the growing oxide scale:
Stages: adsorption of oxidant species → nucleation of oxide → lateral growth to a continuous film → thickening by inward/outward diffusion of metal or oxygen ions with compensating electron transport.
Protective vs non-protective scales: Slow-growing, adherent oxides (e.g., Al₂O₃, Cr₂O₃) can dramatically reduce rates; porous or fast-growing scales (e.g., Fe oxides at high T) often fail to protect.
Mechanical integrity: Growth stresses, thermal cycling, and mismatch in expansion coefficients can crack or spall scales, exposing fresh metal and accelerating attack.
Design levers: choose oxidation-resistant alloys, apply coatings, tailor gas chemistry (e.g., oxygen partial pressure, sulfur content), and manage temperature to stay within kinetic “safe” zones.
5) Molten Salts: Ionic Media with Special Rules
Molten salts are essentially fully ionic liquids (unlike dilute aqueous solutions). Electrochemical cells in these media can extract thermodynamic data, but side reactions and cell stability must be checked—for example, an active metal electrode can react with the melt and silently shift composition, invalidating assumed “steady” emf readings. Material selection in molten salts weighs chemical stability against transport and wetting behavior at operating temperatures.
6) Measuring Corrosion Rates: Instantaneous vs Cumulative
A robust program measures both instantaneous behavior and long-term damage:
Instantaneous electrochemical methods
Linear Polarization Resistance (LPR): small potential perturbation around open circuit; slope gives polarization resistance, which maps to corrosion current (and rate) via the Stern–Geary relationship. Excellent for trending and inhibitor screening.
Potentiodynamic scans: sweep potential to identify passivation, breakdown (pitting potential), and transpassive regimes; useful for mapping thresholds that separate safe from dangerous conditions.
Electrochemical Impedance Spectroscopy (EIS): frequency-domain probe that separates charge transfer, diffusion, and film responses; powerful for diagnosing coating performance and film stability.
Cumulative/nonelectrochemical methods
Mass-loss coupons, thickness measurements, profilometry, and metallography reveal real damage over service-like exposures, capturing phenomena such as localized attack that short electrochemical tests might miss.
Combining approaches lets engineers quickly screen conditions (electrochemistry) and validate service predictions (exposure testing).
7) From Fundamentals to Prevention: A Practical Playbook
With the fundamentals in hand, prevention becomes systematic:
Define environment: chemistry, temperature, flow, deposits, biofouling, impurities (e.g., chlorides, sulfur).
Thermodynamic scoping: use E–pH diagrams and redox data to bound what can happen; identify potential for passivity or aggressive ions that destabilize films.
Kinetic assessment: measure with LPR/EIS/scans; look for thresholds (pitting, crevice breakdown potentials), not just average rates.
Material selection: favor alloys with stable protective films in the target environment (e.g., Cr-rich stainless, Ni-base with Al/Cr for high-T).
Environmental control: adjust pH, oxygen, chloride, temperature; remove deposits; manage velocities to avoid stagnation and erosion.
Barriers and films: apply coatings/linings (e.g., epoxies, 3LPE), encourage passive films, and use inhibitors where appropriate.
Electrochemical protection: design cathodic protection systems (galvanic or impressed current) for buried or immersed assets; in specific cases, anodic protection can stabilize passivity.
Inspection and monitoring: combine online probes (LPR, corrosion coupons), periodic NDE (UT, radiography), and chemical monitoring to close the loop.
Data discipline: correct potentials to the proper reference scale, document IR drop mitigation, and track uncertainty to make decisions with confidence.
8) Key Takeaways
Thermodynamics determines possibility; kinetics/transport determine rate.
Aqueous corrosion is electrochemical; high-temperature corrosion is diffusion-controlled through scales.
Accurate potential measurement (three-electrode setups, reference conversion, IR-drop control) is essential.
Pourbaix diagrams guide, but kinetics and environment decide.
Balanced measurement programs (electrochemical + exposure) support reliable materials selection and life prediction.
Layered defenses—materials, environment control, films/coatings, inhibitors, and electrochemical protection—deliver durable performance.
About the Creator
Sayed Zewayed
writer with a background in engineering. I specialize in creating insightful, practical content on tools. With over 15 years of hands-on experience in construction and a growing passion for online, I blend technical accuracy with a smooth.